G.S Stothers Smoke Ventillation Specialists logo

Life Safety Explained: What is a Smoke Shaft?

Smoke is one of the greatest hazards during a building fire. It can spread quickly beyond the area where a fire originates, reducing visibility, affecting escape routes and creating increasingly difficult conditions for both occupants and attending fire and rescue services.

In multi-storey buildings, managing the movement of smoke through communal corridors, lobbies and stairways is therefore an important part of the overall fire safety strategy.

One solution commonly used to help achieve this is a smoke shaft.

But what exactly is a smoke shaft, how does it work, and what is the difference between natural and mechanical smoke shaft systems?

What is a smoke shaft?

A smoke shaft is a vertical shaft incorporated into a building as part of its smoke control system.

Its purpose is to provide a route through which smoke and heat can be removed from areas such as communal corridors and lobbies during a fire, helping to limit the spread of smoke into protected escape routes.

Smoke shafts are particularly associated with multi-storey developments, including apartment buildings, hotels and other buildings where occupants may need to travel through communal areas before reaching a protected stairway.

However, the shaft itself is only one component of the overall system.

A complete smoke ventilation solution can incorporate smoke control dampers or vents, automatic opening vents (AOVs), detection and control equipment and, in a mechanical system, dedicated extract fans.

These components must work together correctly when the system is activated.

How does a smoke shaft work?

In the event of a fire, the smoke control system responds to a signal from the building's fire detection or control system.

The appropriate smoke control damper or vent on the affected floor opens, providing a route between the corridor or lobby and the smoke shaft. Openings serving unaffected floors remain closed as required by the system strategy.

Smoke can then be drawn or vented into the shaft and discharged from the building.

At the same time, other elements of the smoke control strategy may operate, including an AOV at the head of a stairway.

The exact sequence will depend on the individual building and its fire strategy, which is why smoke ventilation systems must be designed around the requirements of each particular project rather than treated as a standard, one-size-fits-all solution.

Natural vs mechanical smoke shafts

There are two principal approaches to smoke shaft ventilation: natural and mechanical.

A natural smoke shaft uses the natural buoyancy of hot smoke. As smoke rises, the system provides a path through which it can travel upwards and ultimately discharge to the outside.

This approach can provide an effective smoke ventilation solution without relying on mechanical extract fans, but sufficient shaft dimensions, ventilation areas and appropriate building geometry are essential to its performance.

A mechanical smoke shaft, by comparison, uses powered extract fans to actively remove smoke from the affected area.

Mechanical systems can provide greater control over extraction and may be appropriate where space constraints, building configuration or the requirements of the fire strategy make a natural solution unsuitable.

Neither approach should simply be considered "better" than the other. The appropriate solution depends upon the building, its design and the requirements established by the fire strategy.

What is a smoke shaft trying to achieve?

The fundamental purpose isn't simply to "get smoke out of the building".

Smoke control is about managing smoke in a controlled way.

By removing smoke from corridors and lobbies, a correctly designed system can help maintain more tenable conditions within escape routes for longer, supporting occupants as they evacuate the building.

Managing smoke can also support firefighting operations by improving conditions for fire and rescue personnel entering and moving through the building.

This is why smoke ventilation forms an important part of a building's wider life safety strategy.

More than just a shaft

One of the most important things to understand about smoke shafts is that their performance relies on the entire smoke control system.

A perfectly constructed shaft cannot perform its intended function if a damper fails to open, an extract fan doesn't operate or the control system doesn't respond correctly.

Depending on the design, a smoke shaft system may incorporate a number of interconnected elements, including smoke control dampers, AOVs, control panels, detection interfaces, extract fans, power supplies and other equipment.

Each element has a specific role, and the required sequence of operation must occur correctly when the system is activated.

That makes specialist design, installation and commissioning essential.

Getting the design right

Smoke ventilation needs to be considered early within the building design process.

At G.S. Stothers, our technical team works alongside architects, consultants, contractors and other members of the project team to develop smoke ventilation solutions around the specific requirements of a building.

Our design and consultancy capabilities include CFD modelling, free area calculations, regulatory advice and guidance, project design, product selection and CAD/BIM detailing.

Early involvement can help identify potential design and coordination issues before installation begins and ensure the smoke control strategy can be effectively integrated with the wider building design.

Installation is only part of the process

Once a smoke shaft system has been installed, commissioning is essential.

Commissioning allows the complete system and its sequence of operation to be tested to establish that the individual components communicate and respond as intended.

That may include confirming that the correct vent or damper opens, other floors remain appropriately isolated, extract fans operate where required, control panels receive and issue the correct signals and the overall system responds correctly to the fire condition being simulated.

A smoke control system is ultimately a life safety system. It needs to be capable of performing correctly on the day it is required, not simply appear complete at handover.

What happens after handover?

The importance of the smoke shaft system doesn't end when the building becomes occupied.

Smoke control systems contain electrical, mechanical and moving components which need to remain operational throughout the life of the building.

Regular inspection, testing and appropriate maintenance are therefore an important part of maintaining system performance.

Changes to the building should also be considered carefully. Alterations to layouts, doors, ventilation arrangements or other elements of the original design can potentially affect how a smoke control strategy performs.

Complete smoke ventilation expertise from G.S. Stothers

For more than 40 years, G.S. Stothers has specialised in smoke ventilation and smoke control solutions across Northern Ireland and the Republic of Ireland.

Our involvement can begin at the earliest design stages and continue throughout the lifecycle of a system, providing design and consultancy, product selection and supply, installation, commissioning, maintenance and facilities management support.

Smoke shafts are just one part of that expertise.

Whether a project requires natural smoke ventilation, mechanical smoke extraction or a more complex smoke control strategy, our team works with the wider project team to develop and deliver a solution appropriate to the individual building.

Because effective smoke control isn't about one component. It's about ensuring the entire system is designed to work together when it matters most.

Request A Free Professional Survey of your needs